Microscan MS-4X Manuale Utente Pagina 61

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 374
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 60
MS-4X Imager User Manual
3-17
Communications
Daisy Chain ID Status
Note: Enable/disable and length must be the same in all readers.
Daisy Chain ID
Important:
The ASCII characters
<
,
>
, and
,
can only be entered as hex pairs:
For <: <K101h,,,,,,,3C>
For >: <K101h,,,,,,,3E>
For
, : <K101h,,,,,,,2C>
See ASCII Character Entry Modifier for a detailed explanation of how to enter ASCII
characters as hex values.
Usage: Used in a daisy chain setup in cases where the host needs to know which
reader in the chain sent the data.
Definition: Each reader in a daisy chain can be assigned a one or two character ID
that will appear in front of decoded data and identify its source.
Serial Cmd: <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain i.d.
status, daisy chain i.d.>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Usage: Used in a daisy chain setup in cases where the host needs to know which
reader in the chain sent the data.
Definition:
A one or two character prefix which identifies the particular daisy chai
n
r
eader from which the data is being sent to the host.
Serial Cmd:
<K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain
i.d.
status,daisy chain i.d.>
Default: 1/
Options: Any one or two ASCII characters.