Microscan MS-4X Manuale Utente Pagina 161

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 374
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 160
MS-4X Imager User Manual
6-37
Symbologies
MicroPDF417
Fixed Symbol Length Status (MicroPDF417)
Fixed Symbol Length (MicroPDF417)
Note: Fixed Symbol Length Status must be enabled for Fixed Symbol Length to take
effect.
Usage: Used for labelling small items that need large data capacity.
Definition: A variant of PDF417, a very efficient and compact stacked symbology
that can encode up to 250 alphanumeric characters or 366 numeric
characters per symbol.
Serial Cmd: <K485,status,[unused],fixed symbol length status,fixed symbol length>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K485,status,[unused],fixed symbol length status,fixed symbol length>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Usage: Used to increase data integrity by ensuring that only one symbol length
will be accepted.
Definition: When enabled, the MicroPDF417 symbol must contain the same number
of characters as the symbol length setting before it can be considered a
good read. The imager will ignore any symbol not having the specified
length.
Serial Cmd: <K485,status,[unused],fixed symbol length status,fixed symbol length>
Default: 10
Options: 1 to 366