MS-4X Imager User Manual
5-27
Read Cycle
Setting Up the Imager for EZ Trax
If you are using EZ Trax software, it is important to set up the MS-4X correctly before
beginning.
Click the Read Cycle tab to display the Read Cycle tree control.
Set Trigger Mode, <K200>, to External Edge.
Set Capture Mode, <K241>, to Rapid Capture.
Once these Read Cycle parameters are set, you will be ready to connect to EZ Trax. For a
description of how to configure
EZ Trax
using serial commands or
ESP
, see
Configuring EZ
Trax Output
in
I/O Parameters
.
For more detailed information about using EZ Trax, refer to the Help menu in EZ Trax
software, or the EZ Trax Quick Start Guide, available on the Microscan Tools Drive.