Microscan MS-4X Manuale Utente Pagina 305

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 374
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 304
MS-4X Imager User Manual
13-11
Utilities
Master Symbol Database Size
Caution: Since the total number of characters available for the master symbol database is
3000, changes to the Master Symbol Database Size will re-allocate the number of
characters available for each master symbol and could cause existing master symbols to
be deleted (except master symbol #1, unless it also exceeds the size limitation).
The table below specifies the maximum number of characters available to each symbol
according the number of master symbols defined, from 1 to 10.
Definition: Number of Master Symbols allows you to select 1 to 10 master symbols
for the master symbol database.
Serial Cmd: <K231,master symbol database size>
Note:
You must follow this command with a save command
<A>
or
<Z>
.
Default: 1
Options: 1 to 10
Master Symbol
Number
Maximum
Characters
Master Symbol
Number
Maximum
Characters
# 1 3000 # 6 500
# 2 1500 # 7 428
# 3 1000 # 8 375
# 4 750 # 9 333
# 5 600 # 10 300
Set Master Symbol
Database Size here.
Vedere la pagina 304