EZ Match User Manual
12-15
IP Database
Save Current Settings to IP Database
Example:
<K255+,5>
This command phrase saves the imager’s current, active configuration settings to database
index 5.
Save Current Settings to IP Database by ESP
Definition: Allows current, active configuration settings to be saved to a selected
database index.
Serial Cmd: <K255+,index>
Click the Load Current to Index button to
save the imager’s current configuration
parameters to the selected database index.