11-20
EZ Match User Manual
IP Threshold
Cycle Max
Cycle Step
Adaptive Contrast Percent
Definition: Ending value of the cycle mode.
Serial Cmd: <K512,threshold mode,threshold value,cycle min,cycle max,cycle step,
adaptive contrast percent>
Default: 255
Options: 0 to 255
Important: Cycle Max must be a greater numerical value than Cycle Min.
Definition: The numerical value of a single cycle mode increment.
Serial Cmd: <K512,threshold mode,threshold value,cycle min,cycle max,cycle
step,adaptive contrast percent>
Default: 10
Options: 0 to 255
Definition: A percentage value that adjusts the adaptive threshold map; useful in
decoding underprinted or overprinted symbols.
Example: If an adaptive contrast value of 110 is set, then the adaptive
threshold will be 110% of the original contrast values.
Serial Cmd: <K512,threshold mode,threshold value,cycle min,cycle max,cycle step,
adaptive contrast percent>
Default: 100
Options: 1 to 200 (percent)