A-70 QX Hawk Industrial Imager User Manual
Serial Commands
Intensity (Illumination, Standard QX Hawk)
Camera Settings (CMOS)
Shutter Speed (Camera Settings, CMOS)
Gain (Camera Settings, CMOS)
Camera Settings (CCD)
Shutter Speed (Camera Settings, CCD)
Gain (Camera Settings, CCD)
Sub-Sampling
Morphological Pre-Processing
Serial Cmd: <K539,mode,intensity>
Default: 2 = High
Options: 0 = Low 1 = Medium 2 = High
Serial Cmd: <K541,shutter speed,gain>
Default: 2,500
Options: 60 to 40,000
Serial Cmd: <K541,shutter speed,gain>
Default: 20
Options: 0 to 33
Serial Cmd: <K541,shutter speed,gain>
Default: 1,500
Options: 30 to 150,000
Serial Cmd: <K541,shutter speed,gain>
Default: 20
Options: 0 to 64
Serial Cmd: <K542,sub-sampling>
Default: 0 = Disabled
Options: 0 = Disabled 1 = 4:1 2 = 16:1
Serial Cmd: <K550,status>
Default: 0 = Disable
Options: 0 = Disable 1 = Enable