A-66 QX Hawk Industrial Imager User Manual
Serial Commands
Match Replace
Status (Match Replace)
Replacement String (Match Replace)
Mismatch Replace
Status (Mismatch Replace)
Replacement String (Mismatch Replace)
Serial Cmd: <K735,status,replacement string>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K735,status,replacement string>
Default: MATCH
Options: Any valid ASCII string up to 128 characters
Serial Cmd: <K736,status,replacement string>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K736,status,replacement string>
Default: MISMATCH
Options: Any valid ASCII string up to 128 characters