Mirrored
9-20 COPYRIGHT © 2005 MICROSCAN SYSTEMS
Mirrored
Symbols that are mirrored (flipped horizontally or vertically) can only be read if the
Enable Mirrored symbol has been read.
Once an Imager has been set to Enable Mirrored, you can only return to its
default mode by reading the Disable Mirrored symbol.
Enable Mirrored
After reading this symbol,
the Imager will ONLY read
mirrored symbols.
Disable Mirrored (Default)
After reading this symbol, the
Imager defaults to the normal
state and reads ONLY normal
(unmirrored) symbols.
Example of Mirrored Example of Normal
Mirrored symbols can be read on either dark or light backgrounds.