Microscan MS-96 Manuale Utente Pagina 64

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 226
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 63
Good Decode Reads
4-16 MS-9 Scanner User’s Manual
Good Decode Reads
Note: When setting up, be sure to determine if the scanner’s scan rate is capable of
scanning your longest symbol the required number of times.
Usage: This is a very useful feature to increase reliability of reads for symbolo-
gies that do not have internal error checking such as Pharmacode.
Definition: The number of decodes (from 1 to 31) required per symbol before a sym-
bol’s decoded data is sent. It requires the scanner to successfully decode
a symbol a designated number of times (not necessarily consecutively)
before it is sent. If it doesn’t achieve the number of good reads during
the read cycle, then a noread will be sent.
Note: Higher settings will decrease throughput speed.
Serial Cmd: <K221, good decode reads>
Default: 1
Options: 1 to 31
Vedere la pagina 63
1 2 ... 59 60 61 62 63 64 65 66 67 68 69 ... 225 226

Commenti su questo manuale

Nessun commento