MS-Connect 210 User’s Manual 2-11
Using Ethernet
Ethernet Port Custom Features
Serial Configuration Menu
The MS-Connect 210 Ethernet Port’s custom firmware allows the user to access the
Serial Configuration Menu
from Telnet at port 9999 (see
Ethernet Port Operation
),
or from
the RS-232 serial port.
To access the Serial Configuration Menu via the serial port:
At power-on, if the module receives a series of three “x” characters at 9600-8-N-1, the
menu is activated.
The menu allows the user to configure the following:
Network IP, Subnet, Gateway, and Tunneling TCP Port
UART bps, data, parity, stop bits
Dual Mode Connections: Raw tcpserial and EtherNet/IP
Both raw tcpserial and EtherNet/IP connections are available on different TCP ports. The
EtherNet/IP port numbers are defined by that standard. The raw tcpserial port number is
configurable.
Serial UART
The Serial UART can be customized in three ways:
1. The default UART settings are customized to match the majority of Microscan products
(9600 7E1).
2. Packet control options are disabled.
3. Flush Mode options are disabled. All ports are flushed whenever TCP connection
status changes.
The serial port operates in standard RS-232, point-to-point, non-flow control mode.
Parameter Raw tcpserial Port
Default Setting 2001
Optional Setting 1 to 65535
Parameter Bit Rate (bps) Data Bits Parity Stop Bits
Default Setting 9600 7 Even 1
Optional Setting 300 7 None 1
600 8 Even 2
1200 Odd
2400
4800
9600
19200
38400
57600
115200
Vedere la pagina 38