Microscan MS-4X Manuale Utente Pagina 21

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 68
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 20
MS-Connect 210 User’s Manual 1-13
Setup and Operation
Configure Output Settings
Outputs are configured by manipulating the dip switches and jumpers on the board.
Configuring the Outputs and Beeper
The switches for controlling outputs 1, 2, and 3 and the beeper are located at SW5.
Reader Output Reader Output State / Polarity Beeper
Output 1 POS 1 (Up = Normally Open) POS 4 (Up = Off)
Output 2 POS 2 (Up = Normally Open) POS 5 (Up = Off)
Output 3 POS 3 (Up = Normally Open) POS 6 (Up = Off)
Switches at SW5
Polarity Beeper
Output Output
123123
ON
OFFNormally Open / Negative
Normally Closed / Positive
Switches at SW5
The switches at SW5 on the board control polarity and beeper
activity for outputs 1, 2, and 3.
Switches 1, 2, and 3 control polarity for outputs 1-3.
Switches 4, 5, and 6 control the beeper for outpus 1-3.
Vedere la pagina 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 67 68

Commenti su questo manuale

Nessun commento