Chapter 5 Codes
MS-880 Industrial Long Range Scanner User’s Manual 5-5
5–Codes
Narrow Margins
Note: Do not use Narrow Margins with Large Intercharacter Gap enabled in Code
39 or Codabar.
Definition: Allows the scanner to read symbols with quiet zones less than 8 times
the width of the narrow bar element. “Quiet zone” is the space at the
leading and trailing ends of a symbol. Each quiet zone can be as narrow
as only five times the width of the narrow bar element when Narrow
Margins is enabled.
Usage: Used when the leading and trailing edges of the symbols are smaller
than the standard margin or other objects encroach into the margins.
Serial Cmd: <K450,narrow margins status,symbology identifier>
Default: Disabled
Options: 0 = Disabled 1 = Enabled