Output 2
14-10 MS-880 Industrial Long Range Scanner User’s Manual
14–Discrete I/0
Output 2
Output 2 has the same parameters and default settings as Output 1.
Output 3
Output 3 has the same parameters and default settings as Output 1.
Serial Cmd: <K721,output on,active state,pulse width,output mode,trend analysis
mode,trigger evaluation period,number to output on,reads per trigger
threshold>
Serial Cmd: <K722,output on,active state,pulse width,output mode,trend analysis
mode,trigger evaluation period,number to output on,reads per trigger
threshold>