MS-4 Imager User’s Manual 8-9
Symbol Quality
Data Matrix Output Mode
Note: Output Mode applies to ISO/IEC 16022 symbol quality parameters.
Grade
If in
Grade Mode
, a grade (A,B,C,D) is appended to the symbol data.
Value
If in Value Mode, the calculated value for the given parameter is appended to the symbol
data.
Definition: Output Mode specifies how the four output parameters, if enabled, are
formatted.
Serial Cmd: <K708,symbol quality separator,output mode>
Default: Grade
Options: 0 = Grade 1 = Value