Microscan MINI Hawk Xi Manuale Utente Pagina 194

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 388
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 193
7-40
MINI Hawk Xi High Performance Imager User Manual
Database Identifier Output
Database Identifier Output
Output Status
Disabled
When this command is disabled, no database identifier information will be output.
Enabled
When this command is enabled, the imager will append a two-digit number and the characters
“DB” to the data output following the separator for each symbol decoded using
Configuration
Database
. For example, if the separator is an underscore character and the second database
entry reads a symbol encoded with “data capture” during the read cycle, the symbol data
output will be “data capture_DB02”. If the database is not active, no identifiers will be
attached to output.
Separator
Important:
The ASCII characters
<
,
>
, and
,
can only be entered as hex pairs:
For <: <K759h,,3C>
For >: <K759h,,3E>
For
, : <K759h,,2C>
Usage: Useful in keeping track of which database entries read which symbols.
Serial Cmd: <K759,status,separator>
Default: 0
Options: 0 = Disabled 1 = Enabled
Usage:
The separator character separates the symbol data from the database identifier.
Serial Cmd: <K759,status,separator>
Default: <space>
Options: Any ASCII character.