Microscan HS-2D Manuale Utente Pagina 64

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 172
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 63
5-8 HS-21/HS-41X Handheld Reader User’s Manual
Targeting Zone Tolerance
Targeting Zone Tolerance
Targeting Zone Tolerance is particularly useful in environments where closely spaced
symbols of various sizes need to be targeted. It allows the reader to narrow the field of
view relative to the size of a symbol, and to determine the distance the target must be from
the symbol for a decode event to occur.
See Window of Interest for more precise control of the active pixel area.
The default Targeting Zone Tolerance is 1600%.
Formula for calculating Targeting Zone Tolerance:
2 x distance from target to symbol (in pixels) / symbol width or height (in pixels) x 100
Vedere la pagina 63
1 2 ... 59 60 61 62 63 64 65 66 67 68 69 ... 171 172

Commenti su questo manuale

Nessun commento